Technical Information Center

DCFX Series Wire Strippers & Twister

Unit will not strip wires
Ensure wire gauge being stripped is within unit’s specifications.
Adjust speed to higher setting.
Check for dull or damaged blades and replace head if necessary with stripping head.
Check that all 3 blades meet at the same location when closed.
Check for debris in stripping head and motor.
Check to ensure operator is not removing wire too quickly.
Unit cuts wire.
Adjust speed of the power unit to lower setting.
Ensure wire gauge being stripped is within unit’s specifications.
Check operator technique to ensure that wire is being withdrawn quickly enough.
Check that all 3 blades meet at the same location when closed.
Check that wire is free of kinks and bends
Blades grab wire.
Adjust speed of the power unit to a lower setting.
Check for debris in stripping head and motor.
Replace head.
Check operator technique to insure smooth, even withdrawal of conductor.
Too much conductor being removed.
Adjust speed of the power unit to lower setting.
Check operator technique to ensure wire is being withdrawn quickly enough.
Check that all 3 blades meet at the same location when closed. (For all models)
Motor does not run.
Check that all connections are made properly. (Handpiece is plugged into transformer, and transformer is plugged into proper power supply.)
Check fuse in power unit and replace if blown.
Check motor brushes.
Check motor switch
Motor runs slowly.
Check that voltage setting on power unit is properly set.
Check for debris in head, and clean.
Check motor for free rotation. Replace worn bearings.
© Copyright 2026 ∙ The Eraser Company, IncFAQ'sPrivacy Statement